Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
Product
Spectroradiometer
-
Designed to have a capability of producing any visible spectral distribution, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED test system will be used as a transfer standard for photometric, colorimetric and radiometric applications.
-
Product
Aging and Optical Attenuation Tester
LS822
-
• Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.
-
Product
Adjustable High Frequency Reference Ballast
HCS-109A
-
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
Product
CCD Spectroradiometer Integrating Sphere Compact System
LPCE-3
-
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.
-
Product
AC/DC Withstand Voltage Test
WB2671A/WB2671B
-
• Output voltage: 0-5kV (AC/DC); • Cutoff current range: AC 0~20mA (WB2671A)/0~100mA (WB2671B); DC 0-20mA; • Test time: 1-60s; • Transformer capacity: 750VA.
-
Product
Pulse Start Generator for High Pressure Sodium Lamp
LPSG60662
-
The start-up test of the special lights pulse start generator is for lighting class industry such as high pressure sodium, it is according to IEC60662: 2011 and GB/T13259-2005 standard requirements.
-
Product
Goniophotometer for Traffic Signal Lamps
LSG-1950S
-
LSG-1950S is a high automatic test system for luminous intensity distribution of luminaires and can be applied to quality evaluation and quality control for signal luminaires, luminaires for cars, motors, vessels and Retro-reflectors. LSG-1950S system is a goniophotometer which can measure all kinds of lamps and luminaires.• Rotations of test samples around both vertical axis (-90°~+90°) and horizontal axis (-35°~+35°) • Accuracy of angle: 0.1° • Resolution of angle: 0.01° • Photometer detector: CIE class A (standard class) accuracy • All software control, high intellectual faculties and simple operation
-
Product
High Precision Rotation Luminaire Goniospectroradiometer
LSG-1800BCCD
-
LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
Product
Thermal Sensitive Parameter Selector
UI9600
-
Parameter measured under normal temperature:1) β (0-99)2) Switching time T (0.01μs-99.9μs), including Tr, Ts, Tf3) VCES (0-2V), VBE (0-2V)4) Leakage current ICEO (0.01μA-99.9mA)5) Withstand voltage BVCEO (50V-650V)• Parameter measured under high temperature: VBE, β, ICEO
-
Product
Environmental Test Chamber
-
The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip.The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1 and humidity is 0.1%R.HThe temperature sensor is platinum PT100 Ohms/MV resistor
-
Product
Composite Salt Spray Test Chamber
YWX/Q-010X
-
Composite Salt Spray Test Chamber stimulate the actual natural conditions to do accelerated corrosion test, all the testing are based on common states on the natural environmental: such as combine with salt spray, hot air drying, humidity, low temperature and so on. The test samples are widely used on the intense changes in the environment, like automobile parts, aviation equipment, building materials, coating, electric and electrical machinery so on. YWX/Q-150X series is full compliance with ASTM D4728I, EC 60068-2-1, IEC 60068-2-14 and EIA/JEDEC JESD22-110-B standard requirements etc.
-
Product
Digital Power Meter (High Accuracy Model)
LS2050
-
LS2050 digital power meter is a new generation intelligent product which adopts digital sampling technology to analysis of the waveform. It has the following features: • Three windows digital display which reduces reading error, intuitive and convenient • Adopts high speed MCU and high precision A/D to control and measurement • All measured data as virtual value, also suit to signal waveform distortion • Fast test • Equipped with RS232 communicate function, can use upper computer software to carry on remote operation, control and read corresponding data, the test data and waveform could be displayed in the PC, Chinese and English operation interface, high intelligent instrument • This instrument provides two kinds of method to calculate total harmonic distortion (THD), IEC and CSA.
-
Product
MOS Transistor Selector
UI9610
-
MOS with superior performance has now been widely used in electronic ballasts, energy-saving lamps were. But power MOS test screening, matching problem. It is difficult due to a lack of corresponding inspection means that many enterprises do not have to engage seriously in quality control as well as the effect of product consistence and reliability. The equipment in a unique program designed to solve the power MOS test problem containing micro-processing, intelligent a few significant simple application.
-
Product
MOS Transistor Selector
UI9611
-
Measure parameters: Open voltage UGS (th), internal resistance RDS, Transconductance gm, Withstand voltage V (BR) DS• Test range: UGS (th) 0.1-9.9V; RDS 0.001-9.999Ω gm; 0.10-10.00s; V (BR) DS 50-650V• Test current range: 0.1A-5A adjustable, comply with different working situation• Automatic selecting, out of limit alarming, advance the work efficiency• The technique of testing RDS under the big-current, is advanced technique
-
Product
High and Low Temperature Thermal Shock Chamber
HLST-500D
-
The specimen is placed in test chamber specimen which cannot be placed in high temperature chamber or low temperature chamber. High temperature chamber pre-heats the air and low temperature air chamber pre-cools the air. When doing the test of temperature changing from high to low, the low temperature chamber will blow the pre-cooled air to the test chamber. Then, the air in test chamber will reach your target temperature in several minutes (“recover time”). When doing the test of temperature changing from low to high, the high temperature chamber will blow the pre-heated air to the test chamber. Then the air in test chamber will reach your target temperature within the recover time.















