Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
Categories
-
product
LED Power Driver online Tester
WT2080-OK
WT2080-OK LED Power Driver on line Tester is according to GB/T 24825-2009 and IEC 62384: 2006. It suitable for LED Driver production line testing quick test (0.1s finish the testing). The WT2080-OK can test 1pc LED Driver at one time in the production line.
-
product
Electrolytic Capacitor Tester
HF2686C
Test voltage: 0-200V/0-500V• Output current range: 0.1μA-30mA• Maximum charge current: 200mA ±10%• Charge time: 0.5s/1s/2s/3s/4s/5s/7s/10s/30s/60s• Accuracy: ±2%
-
product
EFT Immunity Measurement
EFT61000-4
EFT immunity tester EFT61000-4 is specially designed according to the characteristics and requirements of EFT measurement and it is an ideal disturbance source of EMS measurement. They have fine performance, such as high stability, high reliability, easy to use etc. It meets the standard requirements of IEC 61000-4-4, EN 61000-4-4, GB/T17215.301, GB/T17215.322 and GB/T17626.4. EFT61000-4 has LCD display in both English and Chinese.
-
product
Damped Oscillatory Magnetic Field Immunity Tester
DOMF61000-10
DOMF61000-10 damped oscillatory magnetic field immunity test system included damped oscillating wave generator and single ring coil, it’s designed for to do damping oscillation magnetic field immunity test and fully meet IEC 61000-4-10, EN61000-4-10 and GB/T 17626.10 standards requirement.
-
product
Digital CC and CV DC Power Supply
DC3005
The DC Series Power Supplies are with high stability and high accuracy. The voltage and current can be adjustable and can output costant current or constant voltage. They are suitable to supply DC Power for the standard lamp and the large power LED. Other voltage and current DC Power Supply can be designed according to customer’s request.
-
product
Three Loop Antenna
VVLA-30M
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
product
Medical Masks Synthetic Blood Penetration Tester
WKS-8010
WKS-8010 Medical Masks Synthetic Blood Penetration Tester is to test the mask material with synthetic blood under continuous pressure, and visually inspect the penetration of synthetic blood on the material. It is suitable for the resistance of masks to the penetration of synthetic blood under different levels of test pressure.
-
product
GNG-* “Go” and “Not go”gauge
GNG-*
According to the requirement of IEC 60061, Lisun produced high accuracy and high quality “Go” and “Not go” gauge • GNG-E27 is for E27 lamp cap standard source measurement. It includes 7006-27B-1, 7006-28A-1, 7006-27C-1, 7006-50-1, 7006-51A-2, 7006-51-2 • GNG-E27H is for E27 lamp holder standard source measurement. It includes 7006-25A-2, 7006-26-4, 7006-21-5, 7006-22A-4, 7006-22B-1, 7006-22C-1, 7006-22D-1 • GNG-E14 is for E14 lamp cap standard source measurement: 7006-27F-1, 7006-54-2, 7006-27G-1, 7006-55-2 • GNG-E40 is for E40 lamp cap standard source measurement: 7006-27-7, 7006-28D-1, 7006-52-1, 7006-53-1 • GNG-B22D is for B22d lamp cap standard source measurement: 7006-12-8, 7006-15-7, 7006-20-4, 7006-12A-2, 7006-12B-2, 7006-15A-2, 7006-13-5, 7006-17B-1 • GNG-B22DH is for B22d lamp holder standard source measurement: 7006-12A-2, 7006-12B-2, 7006-15A-2, 7005-10-8
-
product
RF Conducted Immunity Test System
RFCI61000-4-6
RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.
-
product
DC Bias Current Source
FD1772B
• Constant DC output 0-6A• Auto or manual current sweep output• 5 current range output• Output voltage range: 0-11.5V• Current accuracy ± (1%reading + 2digit)
-
product
Thermal Resistance Spectroradiometeric System for LED
TRS-1000
Thermal parameter is the key index to evaluate the quality of LED. Different temperature will have significant different effects on optical parameters, color parameters, electricity parameters and life of LED. Therefore, design and control of the thermal dissipation are the most important thing for the manufacturers and users. Referring to the relative international standard, TRS-1000 could conduct integration testing on optic, color, electricity and thermal, meanwhile record the changing curve of the parameters at real time.
-
product
Thermally Protected Ballast Heating Test Chamber
TPB-UL935
Working room dimension: 610×610×610mm• Temperature range: RT+10℃~+100℃• Materials of inner and outside chamber: Senior stainless steel• Insulation Material: Ultra-fine glass wool insulation material• Heater: Dedicated strip heater (heating surface area of 300 × 40 mm), each group three hundred watts, a total of four groups, with the power supply in parallel.• Special wooden test sample holder• Third gear temperature measurement points (at any time monitoring and conversion)
-
product
Masks Respiratory Resistance Tester
WKS-1200
WKS-1200 Masks Respiratory Resistance Tester applies to determining the inhalation resistance and exhalation resistance of respirators and mask protective products under specified conditions, and used for the relevant testing and inspection of ordinary mask products by the national labor protection equipment inspection agency or manufacturer.
-
product
Output Characteristic Analyzer of Electronic Ballast
UI2002
• Measure lamp voltage, lamp current, lamp power, oscillatory frequency, filament current, guided cathode current, and crest factors • Measure changing curves and values of startup lamp voltage, lamp current, filament current, cathode current from 0 to 5 seconds, as well as the pre-heat time • Accuracy: Class 2 • Data and curves printable. All the data and curves can be displayed after being connected with PC
-
product
High Accuracy Spectrophotocolorimeter
LMS-3000
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃