Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
Categories
-
product
LED Test Instruments
Photobiological Safety of Lamps and Lamp System and IEC TR62471-2(2009) Guidance on Manufacturing Requirements Relating to Non-laser Optical Radiation Safety have be published addressing hazard to human (mostly eye and skin), and are completely suitable to assess the optical radiation safety of non-laser sources, such as LED products, UV radiation in general lighting products and etc.
-
product
High Precision Rotation Luminaire Goniophotometer
LSG-1800B
LSG-1800B Goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
LED Driver Online Tester
LEDLS-60/LEDLS-12
• The tester includes A Group Measuring Module and B Group Measuring Module. The A Group measuring module can test 6pcs LED Driver AC Parameters. The B Group measuring module can test 6pcs LED Driver AC, DC and AC/DC Parameters. • There are 12 windows to display the input and output parameters, it is good for comparing and analyses. • Quick test for all of the parameters in 0.1 seconds. • It can set up the testing parameters PASS/FAIL range, it will have Noise/Light warning if it is Fail. We also supply handle port (Extra cost) • Software communicate with PC (Extra cost)
-
product
EMI Receiver System
EMI-9KC/EMI-9KB
EMI-9KB is an automatic EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.
-
product
Electronic Components Test
Parameters to be measured (absolute value): Measure hypo-class U, Iout, Hz, Hc, Br, Bm, Hm, Br /Bm, m, magnetic core loss, B-H curve, U curve and I curve Output capacity of the high frequency power: Uout: 1~300V, Iout: 0.05~5A, Pout: 300VA, frequency: 10~300kHz Accuracy: 2% With 12-bit high-speed A/D, sampling rate up to 40MHz, ensuring data precise and stable test result Supermaximal database, suitable for almost all kinds of magnetic material in market, such as: circle, E ,U , ETD-EER, JAR, RM , EP , PM , EL , ER, PQ, EFD, plane E, etc Perfect software interface enables observation of curve in detail Meet international test requirements for magnetic particle ASTM E1444, ASTM E709-08.
-
product
CCD Spectroradiometer
LMS-8000A/LMS-8000
LMS-8000A/LMS-8000 LED Measurement System is an automated measurement system for identifying the performance of individual LED. It is designed to have a capability of producing any visible spectral distribution, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED test system will be used as a transfer standard for photometric, colorimetric and radiometric applications.
-
product
Salt Spray Test Machine
YWX/Q-010
The Salt Spray Test Machine/Chamber is applicable to the salt spray corrosive test for the protection layer of components, parts, electronic and electrical parts and metal materials and industrial products. • The Salt Spray Test Machine is made of transparent materials so that the operator can see the tested sample in it and the spraying situation of the tested sample. • A waterproof structure is adopted between the chamber cover and chamber body, thus there is no salt spray overflow. • Adopts the tower spraying system and equipped with the salt solution filter system and non-crystal nozzle so as to realize even salt spray distribution and freely adjustable settlement. • It meets the following standards: IEC60068-2-11 (GB/T2423.17), GB/T10125, ISO9227, ASTM-B117, GB/T2423-18, IEC 60068-2-52, ASTM-B368, MIL-STD-202, EIA-364-26, ASTM-B117, GJB150, DIN50021-75, ISO3768, 3769, 3770; CNS 3627, 3885, 4159, 7669 etc.
-
product
Absorbing Clamp
AB-CLP
• EMI Receiver equipped with absorbing clamp can indirectly test radiated interference power of household electrical appliance, power tool and similar electrical appliance with frequency from 30~300MHz.
-
product
Multiway Life Tester
CH316
Measure 16 samples at the same time, evaluate and record the life of each sample. Very flexible: Samples can be added and changed at anytime. The life of each sample is readable at anytime. The switch ON/OFF time is adjustable (Test period is min 1s). Automatically remember the test result when the power is off, and resume the old measurement when power is on. Sound and light alarm when the products were failed.
-
product
HVR-LS Horizontal Vertical Flame Tester
HVR-LS/HVR-LSS
This equipment meets the requirements of ANSI/UL94, IEC60950-1, IEC695-2-2 and GB Standard. It is used to test the appliances and plastic materials parts of electrical equipment for the horizontal, vertical flammability test. The product tank shell is irony spray, and configured a transparent viewing window, the digital meter shows the burning time, afterflame time, afterglow time, this device has beautiful appearance, is easy to use and has reliable performance.
-
product
New Design 3m Electric Integrating Sphere
IS-3.0MA
It has all functions of IS-*MA Integrating Sphere with Holder Base.• Lisun engineers add the infrared anti-pinch device (the video please come to the “video” tab) and the cross laser positioning device in the integrating sphere.• Please refer to article The New Design 3m Electric Integrating Sphere for more information.
-
product
Voltage Dips and Interruptions Generator
CSS61000-11
The voltage dip and interruptions generator is specially designed according to the characteristics and requirements of EMS measurement under a sudden reduction or interruption of the voltage at a point, CSS61000-11/ CSS61000-11T used a big LCD in both English and Chinese operating interface. They have more fine performance such as high reliability, convenient operation, and full meet the standard requirements of IEC 61000-4-11, EN 61000-4-11 and GB/T17626.11
-
product
Low-Temperature Impact Device
DWC-1
This low-temperature impact device is compliance with standard requirement of IEC60245, IEC60227, IEC60540, GB5013-2008, GB5023-2008 and GBT2951-2008. It’s used to test all kinds of PVC sheathed cable, wire, soft wire and no sheath of parallel soft PVC insulated impact resistance at low temperature. Specification: • Working temperature: -15℃±1℃ • Impact height: 10~200mm adjustable • Length of specimen: 5D~150D • Material: 304 stainless steel • Completion time once: 3~5s • Completion number of units for once: ≥2pcs • Weight: 100/200/300/400/500/600/750/1000/1250/1500g • Low temperature box to match additionally
-
product
Luminance Colorimeter
XYL-VI
The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs the digital X(λ), Y(λ), Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal measurement system to replace the traditional analogue measurement system. The instrument has no analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong anti-interference ability and it has high accuracy. The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color coordinates and color temperature. It is a real-time measuring system and run under Windows2000/XP.
-
product
Rotation Luminaire Goniospectroradiometer
LSG-1800CCD
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.