Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2X
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
AC/DC Single Phase Digital Power Meter 100 kHz
T3PM1100
Power Meter
AC/DC Single Phase Digital Power Meter 100 kHz.
-
Product
28 Days Test Bench (Single Phase & Three Phase)
-
The SCR Elektroniks 3 station MCB 28 Days and Temperature Rise Test Bench is economically designed to verify the 28 Days Test (21 hr ON, 3 hr OFF Test) as per clause 9.9 of IEC 60898-1 and Temperature Rise of the parts of a Circuit Breaker specified in Table 6 of clause 8.4.1 measured under the conditions specified in clause 9.8.2 of IEC 60898-1.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T156
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standards
7X
-
WENS series Frequency / Voltage / Wave / Carrier Standards is an ideal and smart solution for distributing signals from Quartz or GPS receivers. Designed to multiple output for multiple applications.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-3
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I15-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Non-Contact Type Phase Sequence Indicator
895 PR
-
Standard Electric Works Co., Ltd
Protection class: IP40. Non-contact detector clips. No metal contact points to advocate greater safety. Two functions in one unit : open phase and phase sequence detection. Designed for checking a wider range of 3-phase power sources. LED display lights with buzzer indicator. Brightness button feature for better visibility in dimly lit areas or sunlight. Magnetic mounting feature.
-
Product
Time & Frequency Standards
Meridian II Precision TimeBase
-
The Meridian II Precision TimeBase is a modular, network-centric, time & frequency standard that provides the most precise and stable, GPS-synchronized, time & frequency outputs in the world. Unlike our competitors, we fully specify the performance of Meridian II and back it up with published data measured at NIST.
-
Product
Fully Automatic Close Link Single Phase Energy Meter Test bench
SY8125
-
Hong Kong Songyang Industrial Ltd.
The devices are fully made by aluminum alloy materials and the table board is composed of fireproofing and heat-proof materials. ● The output voltage and current use soft startup and stop. It has the protection functions of voltage short circuit, current open circuit and power amplification exception.● The device has the features of high stability, good reliability and large output power. ● High level of autoimmunization. The coexistence of special small keyboard and PCs, convenience to use.
-
Product
"Standard" RF Low Pass Filters
-
Coaxial Dynamics "Standard" line of RF Low Pass Filters offers several models to choose from at CW power ratings of 100 watts and 200 watts. These filters cover operating frequencies from 88 MHz to 400 MHz with less than 0.5 dB insertion loss and attenuation levels of 40, 50 and 60 dB.
-
Product
Digital Multimeter and Phase Rotation Tester
3000 MPR
-
Standard Electric Works Co., Ltd
● 4000-count LCD● Auto ranging● Voltage, Resistance, Current, Continuity, Diode measurement● Can measure Resistance up to 200.0 Mohm● Checks a wide range of 3-phase power sources (80~750VAC)● Phase Rotation indication : clockwise and counter-clockwise on LCD● The LCD will show AC voltage between phases and Phase Rotation● Wide range for capacitance test: 0~40000μF(40.00mF)● REL / Auto-Zero function● MAX /MIN function● VAHz function● Frequency : 40.00 MHz● Data hold function● Over range indication● Low battery detection● Auto power off in 15 minutes● Convenient stand for viewing● Comply with EN 61010-1, CAT III 600V for the range of 600V AC/DC
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Single Phase Meter Test Bench
-
Supreme Instrument Laboratories
Single phase meter test bench suitable for calibration & testing of AC Ammeters, AC Volt Meters, AC Single phase Energy Meters, Power Factor Meters & Watt Meters. Other Technical Specifications are as under
-
Product
3 Phase Meter - Clockwise
135007
-
IEC 1010 Rating: 1000V Cat III/600V Cat IV Double/Reinforced Insulation Features: For Use In The Installation and Operation Of 3 Phase Equipment.
-
Product
PCI Standard Programmable Resistor Cards
-
Pickering's PCI Standard Programmable Resistor Cards include fully programmable resistor and potentiometer cards for applications such as sensor emulation that require fine adjustment with a resolution down to 0.25 Ohm. All of our Programmable Resistor Cards can easily be formed to make Programmable Potentiometers by connecting two channels in series, using the unconnected terminals as the A and B connections and the link between the two channels as the wiper connection.
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25F-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Standard Tests
-
The following list contains only the most important standards and does not claim to be complete.EN 60204-1 Electrical equipment of machinesEN 60335-1 Electrical appliances for household and similar useEN 50106 Sampling test, routine tests (in conjunction with EN 60335-1)EN 60598-1 LuminariesEN 60601-1 Medical electrical equipmentEN 60730-1 Automatic electrical controlsEN 61010-1 Measuring, control and laboratory equipmentEN 61439-1 Switch cabinet and switchgearEN 62368-1 Equipment for audio/video, information and communication technologyEN 62841-1 Hand-held electric toolsEN 50191 Erection and operation of stationary and non-stationary electrical test equipmentLVD Low V oltage D irective _
-
Product
Standard Transmitter
Tipix 2200
-
The TIPIX 2200 is a transmitter purposely designed for deep Induced Polarisation or Resistivity sounding investigations. This transmitter is generally used together with V-Fullwavers or Elrec Pro receivers. This entry-level instrument has been designed for an ease of use and for a good productivity together with a strong protection against misuse. This very robust device has proven to be reliable even in very cold weather (up to -40°C) or in wet environment. It is able to inject up to 2200W in the soil and to inject up to 13A, so that it is suitable, even on conductive soils, to measure resistivity and IP at medium range depths. It is powered by standard generator.
-
Product
Phase Angle and Power Factor Transducer of Single-phase AC Electric Power
NMTFi
-
The NMTFi device is a phase angle and power factor transducer operated in single-phase power network and featuring two independent analogous outputs. The A output measures the phase angle between voltage and current, the B output measures the power factor. In such a was one single NMFTi transducer is able to replace two customary transducers thus making it possible to achieve significant savings in installation space.
-
Product
Digital Phase Shifters
-
An electronic device that changes the timing (phase) of an RF/microwave signal in precise, stepped increments, controlled by digital signals (like 0s and 1s), not continuously like analog versions.
-
Product
High Frequency Standard Capacitor
GenRad 1403 Series
-
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.
-
Product
Automated Temperature Resistance Standard
-
Measurements International Ltd.
Exceptional Stability, Cost-effectiveness, Performance-based Results, 10 Ω, 25 Ω, 100 Ω, 200 Ω, 400 Ω and 1000 Ω Internal Standards, Built-in Temperature Chamber for Optimal Performance.
-
Product
Phase Noise Analyzer
NXA-50
-
This new NXA-50 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 50 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
3 Phase Voltage Extension To Turns Ratio Meter
T-REX
-
The Raytech three phase voltage system option T-Rex is an optional system accessory for 3-Phase transformer ratio meter test sets designed by Raytech (i.e. TR-MARK III). T-Rex was designed to give Engineers and Test Technicians the ability to test the phase relationships and actual voltage ratios of transformer windings while applying three phase voltage.
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-2R1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Rubidium Standard with Optional DDS Signal Generator
1450B
-
The 1450B outputs can be configured as sine waves or square waves and can provide frequencies of 10MHz, 1MHz, 100kHz, 1pps or optional signal generator outputs. The signal generator outputs use direct digital synthesizer (DDS) technology and are confirurable from 100Hz to 171MHz. The 1450B also includes a 1pps input that can be used to discipline and automatically calibrate the 1450B. The 1pps input signal is typically obtained from an external device like a GPS frequency receiver/antenna. The Novatech GPS1 Smart Antenna with 1pps output is available as an accessory to provide a complete turnkey solution.