Phase Standards
verify Phase Meters, Vector Voltmeters, Broadband Wattmeters and Power Analyzers, Resolvers and other Phase Sensitive Instruments.
See Also: Phase, Phasing, Phase Meters, Phase Angle, 3 Phase
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Modal Analysis
-
EDM Modal Standard Modal Analysis provides the user with a complete arsenal of tools, from FRF data selection and parameter identification to results validation and mode shape animation.
-
Product
ANSI Standard Burden Sets
Voltage and Current
-
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
Product
GFS Primary Gravimetric Flow Standard
-
The GFS dynamic gravimetric mass flow calibration system allows users to maintain the accuracy and traceability of molblocs or other high precision devices using the same primary reference used by Fluke Calibration. GFS is a true mass flow reference suitable for use in premier measurement institutes who require the lowest measurement uncertainty.
-
Product
Standard And Custom Targets
-
Santa Barbara Infrared manufactures a wide range of targets for visible, and infrared/FLIR electro-optical testing. These targets complement our complete line of Visible and IR test products. Our targets are designed to function with one of SBIR’s target wheels. Utilizing a variety of manufacturing techniques, including conventional machining, photochemical etching, electro-deposition, electrical discharge machining (EDM) and laser cutting. SBIR targets are manufactured to exacting mechanical tolerances. SBIR manufactures all of the targets specified by MIL-STD-1859 and the Tri-Service Guide for thermal imager testing.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1H-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Single Phase Double Channel Energy Meter Test Equipment
SY8126
-
Hong Kong Songyang Industrial Ltd.
SY8126 single phase Energy Meter Test Equipment is a new generation, high precision, energy meter calibration equipment. It uses the international’s most advanced technology and components available in 90 decade. The equipment works under the control of keyboard or remote computer.
-
Product
Single Phase Lock-In Amplifier
SR510
-
Stanford Research Systems, Inc.
The SR510 and SR530 are analog lock-in amplifiers which can measure AC signals as small as nanovolts in the presence of much larger noise levels. Both the single phase SR510 and the dual phase SR530 have low-noise voltage and current inputs, high dynamic reserve, two stages of time constants, and an internal oscillator.
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25C-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Regenerative AC Emulator, 600 VAC, 125 A, 90 KVA, 3‑Phase
SL1203A
-
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
Product
Viscosity Standards
-
Brookfield Viscosity Silicone and Oil Standards provide a convenient, reliable way to verify the calibration of your Brookfield laboratory viscometer/rheometer.
-
Product
Nanoscale Microscopy Standards
-
The nanoscale AFM-CD standard (CD, critical dimension) contains structures to calibrate line widths and periods of AFM (atomic force microscopy) devices.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1H-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L24-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
903 Benchtop Three Phase 40A
-
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.
-
Product
Oil Immersed Transfer Standard
esi SR1030 Series
-
The esi SR1030 transfer standards consist of 12 equal steps. These steps are available in increments of 1 (SR1030-1), 10 (SR1030-10), 100 (SR1030-100), 1k (SR1030-1k), 10k (SR1030-10k) and 100k (SR1030-100k). The esi SR1030 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature. The esi SR1010 and esi SR1030 are used for the same applications and are alike in configuration. The esi SR1030 differs from the esi SR1010 in that it is specially sealed, and values below 100 k are filled with oil to improve changes due to thermal variations.
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-F
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1W1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25HL-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1UN-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Voltage 37 Pin D-Type Connector Blocks for Pickering
-
The connector blocks below are suitable to use with Pickering cards and modules that utilize a standard voltage 37-pin D-type connector.
-
Product
Sematech Analysis and SEMI Standards Analysis
-
Rocky Mountain Laboratories, Inc.
Rocky Mountain Laboratories, Inc. provides SEMI Standards analyses that conform to the following SEMATECH and SEMI Standards for testing of passivated 316L stainless steel components being considered for installation into a high-purity gas distribution system:SEMASPEC #90120401B-STD (SEM Analysis)SEMASPEC #90120402B-STD (EDS Analysis)SEMASPEC #90120403B-STD (XPS Analysis)SEMASPEC #91060573B-STD (Auger (AES) Analysis)SEMI F60-0306 (based on F60-0301) (XPS Analysis)SEMI F72-1102 (Auger (AES) Analysis)
-
Product
Standard Voltage 37 Pin D-Type Cables - Connector to Connector
-
The connector to connector cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I8-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
NF-Series Standard Plus Models
-
The E-DRIV® NF-Series standard plus models feature a selectable Double Hit Mode for soft joint applications and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The NF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.
-
Product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-0
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Phase Detectors
CD series
-
The CD series is a phase detector module. It is possible to detect small level signal and signal buried in noise.
-
Product
Calibrated Diffuse Reflectance Standards
-
Diffuse reflection calibration standards in synthetic ODM and ODMP material
-
Product
Phase Noise Measurement Solution, 50 kHz to 110 GHz
E5505A
-
The Keysight Technologies E5500 Series of phase noise measurement solutions offers the most flexible set of measurements on one-port VCOs, DROs, crystal oscillators and synthesizers. Two-port devices, including amplifiers and converters, plus CW, pulsed and spurious signals can also be measured. The E5500 measurements include absolute and residual phase noises, AM noise, and low-level spurious signals. The stand-alone instrument architecture easily configures for various measurement techniques, including the PLL/reference source technique, residual and FM discriminator methods.





























