Phase Standards
verify Phase Meters, Vector Voltmeters, Broadband Wattmeters and Power Analyzers, Resolvers and other Phase Sensitive Instruments.
See Also: Phase, Phasing, Phase Meters, Phase Angle, 3 Phase
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25H-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
Product
Regenerative AC Emulator, 600 VAC, 63 A, 30 KVA, 3‑Phase
SL1201A
-
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.
-
Product
Standard & High Speed Amplifiers
-
Advanced Energy's Trek high voltage power amplifiers employ unique and proprietary circuitry. Benefit from closed-loop amplifier systems that feature exceptional DC stability and excellent wideband performance characteristics. And thanks to all-solid-state designs, our amplifiers are protected from output short circuits and overvoltages.
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62H-4-S
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Phase Splitter Comb Generator
-
*Differential output - can also provide single ended outputs, one with positive going pulse, the second with negative going pulse. * Pulse height adjustable +1 to +5V peak into 50 ohms, on positive output, with concurrent -1 to -5V peak on negative output * Produces differential pulse on positive edge of input clock * Input clock may be 20-100MHz sinewave or 0.5-100MHz square wave, producing comb to 4GHz. Usable energy to >10GHz. * Differential outputs are designed to drive matched 50 ohm loads, but can drive any load, including short, without damage. Has integral fan. * Power Requirements: -12V @ 120mA and +18V @ 90mA.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
High Frequency Probe
Your product description goes here.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3C
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
Mechanical Calibration Kit
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.
-
Product
Charge Coupled Device (CCD) Standard Image Sensors
-
Teledyne e2v is the leading supplier of scientific grade Charge Coupled Device (CCD) image sensors for the most challenging low light imaging and spectroscopy applications.
-
Product
SiTek Standard PSD
1L20_CP3
-
The SiTek Standard PSD (Position Sensing Detector) has high resolution, fast response and outstanding linearity. It is used in a wide variety of applications, most of them utilizing light sources in the visible or near-infrared part of the spectrum. The spectral range covers the region 400 - 1100 nm. Thanks to SiTek's proprietary AR-coating, optimized around 860 nm, a reflection loss of only 2% is achieved around the responsivity peak. Most of the detectors have a cover window to avoid handling damages.
-
Product
GPS Frequency Standards
-
Precision Test Systems manufacturers' a full range of GPS and GNSS frequency standards that are disciplined to most of the worlds satellite systems.
-
Product
Standard Voltage 50 Pin D-Type Connector Blocks and Breakouts for Pickering
-
The connector blocks and breakouts below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5B
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
NanoCD Standards (NCD)
-
The NanoCD™ (NCD) is the first commercially available standard to provide line width accuracy calibration at the 45 nm, 65 nm, 90 nm and 130 nm nodes. Use these standards for tool matching, calibrating the width of a CD-AFM tip, or CD-SEM diagnostics.
-
Product
Phase Failure Detectors
DSP
-
Your product The DSP-1L or DSP-1LM is used to protect your three-phase motors against phase loss, imbalance, or reversal. It continuously monitors each phase of your power supply. In case of a problem, it cuts the power to the control circuit to protect the affected motor.
-
Product
Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0B
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Three Phase Coupling/Decoupling Network
CDN 3043 Series
-
- Compliant with IEC 61000-4-4 & 5- Universal teminals- no special plugs required- Safety HV plugs and terminals-Manual/programmable EUT power ON/OFF control- Short term overstress capability
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25A-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-H150-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard & Custom Test Fixtures
-
Both standard and custom Test Fixtures from OAI enable the user to integrate the solar cell with the I -V tester. Fixture configurations range from from simple hold down devices to temperature-controlled fixtures with front and back side contact. We invite you to contact an OAI Application Engineer for help with your fixture design. With our expert guidance, you can expect maximum performance from your I -V Tester and Solar Simulator.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Voltage Controlled Phase Shifters To 3200 MHz
-
Pulsar's Voltage Controlled Phase shifters utilize a DC voltage to control the phase of the RF signal applied. These phase shifters utilize varactor diodes to produce the necessary phase requirements. Phase of the 180 and 360 degree designs are available, and phase can be controlled with a DC voltage 0-20 Vdc. Modulation of these phase shifters is typically 100 kHz, and maximum input power is +5 dBm.A wide variety of package styles are available, such as plug-in, flatpack, TO-cans, and connectorized housings, though the most popular are the miniature surface mount packages. Surface mount packages are available on tape and reel, for automated assembly techniques.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I40-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Industrial Ovens
-
ESPEC offers two types of standard models: the space-saving PV vertical ovens and the PH horizontal ovens. Both provide horizontal airflow for even exposure to all samples. Control constancy as low as ±0.1°C and uniformity as low as ±0.5°C ensures accurate operation. An exhaust damper is included to ventilate the oven and allow quick cool-down.
-
Product
Single Or Dual Stream MIL-STD-1553 A/B &4, 8 Or 12 Channel ARINC429 Mixed ProtocolTest & Simulation Module For Standard Ethernet
ANET-MxAy
-
Single or dual stream MIL-STD-1553 A/B and 4, 8 or 12 channel ARINC429 mixed protocol Test & Simulation module for standard Ethernet. The ANET embedded Linux operating system gives the unique capability to run the optional PBA.pro Engine right in the box.Another option is the ANET-ADK onboard software development kit where users create runtime applications (e.g. MIL-STD-1553 to Ethernet Converter / ARINC429 to Ethernet Converter , MIL-STD-1553 to Ethernet Gateway / ARINC429 to Ethernet Gateway) to execute right in the box. For wireless applications an ANET compatible USB Wifi dongle is optionally available. The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET docking station to host up to 4 ANET modules.