Lisun Electronics Inc.
Lisun Electronics Inc was found by Lisun Group in 2003. We have sales & service offices in Shanghai, Russia, India and Korea. In 2012, we built a high level products show room & lab center in Shanghai. Lisun Group has set up a new manufactory in China to research and develop the world high-technology CFL & LED Test Instruments. Its quality system has been strictly certified by ISO9001:2008. The Lisun Group products have been authenticated by the third party lab and were awarded by CE certificate. As a CIE Supportive Member, all of the test instruments produced by Lisun Group are designed according to CIE Standards.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
product
Fluorescent Lamp Asymmetric Pulse Tester
UI2002C
UI2002C is designed according to the latest update in IEC 61347-2-3 about the test requirements for local rectifying effects on tubes. It imitates the condition when tube is under local rectifying status and tests the abnormal protection function of ballast by adopting fluorescent lamp asymmetry pulse test method with 3 windows for displaying rectified voltage, rectified current, and rectified power. It is easy for operation and with high test accuracy. • Measure lamp voltage, lamp current , average and total power of lamp. • Lamp voltage range: 10~300V • Lamp current range: 10mA~1.0A • Lamp power range: 0.5~300W • Tolerance is 5%
-
product
Electrodynamic Vibration Generator System
LVD-100KG
• Vibration table size: 500*500mm (Other size can be designed) • Vibration: 0~5mm (Adjustable range P-P). Vibration waveform: sine wave (half wave and full wave). Acceleration speed: 0~20g (Adjustable) • Maximum test load Capacity: 100kg • Accuracy: Frequency can be displayed to 0.01 Hz. Precision 0.1 Hz. • Sweep Frequency function (1~600Hz): (Upper frequency, Lower frequency, Time range) It can set real standard arbitrarily to sweep frequency back and forth • Programmable Function (1~600Hz): It can set each segment in 15 segments arbitrarily (frequency/amplitude/time/acceleration), and it can be recycled • Frequency doubling function (1~600Hz): 15 segments multiplied-increase: 1)Low to high frequency 2)High to low frequency 3)Low to high and then to low frequency, it can be recycled • Logarithmic function (1~600Hz), 3 modes of logarithm/can be recycled: 1)Lower to upper frequency 2)Upper to lower frequency 3)Lower to upper and then to lower frequency • Measuring instrument: To display amplitude, acceleration speed and the maximum acceleration speed.
-
product
High and Low Temperature & Low Pressure Chamber
LAP-100
It is according to GB10590 / GB15091 low temperature / low pressure test chamber requirements; GB11159 low pressure test chamber requirements; GB / T2423. 25-1992 low temperature / low pressure integrated chamber requirement; GB / T2423. 26-1992 High temperature / low pressure integrated chamber requirement; GJB150. 2-86 low temperature / low pressure test etc standards. It’s used to test the In aviation, aerospace, information, electronics and other fields, to determine the instrumentation, Electrical products, materials, components, equipment etc.
-
product
Portable CCD Spectroradiometer
LMS-6000
The Portable CCD Colorimeter Spectroradiometer has the following versions which can measure different parameters: • LMS-6000: illuminance (lux), E(Fc), Ee(W/m2), Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram • LMS-6000L: cd/m2, fL, Tc (K), Duv Correlated Color Temperature (CCT), Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree, Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram • LMS-6000P: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio • LMS-6000S: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb_Ratio, Rf and Rg according to TM-30 • LMS-6000F: LMS-6000 Parameters+Flicker test • LMS-6000B: LMS-6000 Parameters+Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002 • LMS-6000BF: LMS-6000 Parameters+Flicker test, Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE S009/E:2002
-
product
Absorbing Clamp
AB-CLP
• EMI Receiver equipped with absorbing clamp can indirectly test radiated interference power of household electrical appliance, power tool and similar electrical appliance with frequency from 30~300MHz.
-
product
Thickness Meter for Phosphor Coating
PM200T
PM200T is applicable for the manufacturers of fluorescent lamp. During the procedure of powdering tube, PM200T solves the problem efficiently how to control the phosphor thickness and uniformly of the tube. It becomes the important tool to reach best lumen output and save the phosphor.
-
product
Quick-Scan Spectrophotometer Colorimeter
LMS-5000
LMS-5000 Quick-Scan Spectrophotometer Colorimeter is a very widely applied single monochromators spectrophotometer with high accuracy. A typical measuring time during the spectral range from 380~800nm is less than 10 seconds. LMS-5000 used with right size integrating sphere and standard light source can be applied to do spectral measurement of LEDs, LED modules, CFL, Fluorescent Lamp, CCFL, HID lamps and other luminaries.
-
product
Rotation Luminaire Goniospectroradiometer
LSG-1800CCD
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Automatic Safety Test System
LS9955/56
The LS9955/LS9956 Automatic Safety Test System is according to GB4706.1, IEC/EN60335-1, UL60335, GB7000, IEC60598, GB4943, IEC60950 and GB9706.1. It used for luminaries, home application and motor tools safety test in production line or Lab R&D.
-
product
Digital Colorimeter & Illuminance Meter
CHC-I
This Digital Color Meter & Illuminance Meter is based on all digital integral photometric and colorimetric measurement technology. It has no analogue unit, thus it is very simple to overcome the zero drift which is impossible to be avoided in current colorimeter. The digital X (λ), Y (λ), Z (λ) sensor has large dynamic range so that there is no range-changing error in it; moreover, it possesses strong anti-interference ability and high accuracy. The CHC-I contains internal RS232 computer interface, the calibration is done by software. It is suitable for monitoring and remote applications. The CHC-I software can calibrate the instrumentation, sample the data through RS232 interface and print out the results. It can also be calibrated by other standard light sources to obtain very high measuring accuracy of x, y color coordinate and color temperature. It is a real-time measuring system and run under Windows System. 128*64 lattice LCD display, RS232 computer interface and software, Data hold function.
-
product
Lamp Cap Temperature Rise Test System
TMP-L
TMP-L is according to IEC60360-1998 and GB2512-2001 (Standard method of measurement of lamp cap temperature rise). It is used to test the working and environmental temperature as well as temperature-rise of the burner and lamp. It meets the requirement of IEC and GB Standards.
-
product
Reflection/Transmission Test Chamber
CHTR-100
When measure the surface spectral reflectance of all kinds of reflect mirror, metal, plastic and so on or the spectral transmission of glass and plastic, CHTR-100 Reflection/Transmission Test Chamber is mainly used to collect photometric and chroma energy, and then send the tested light signal to spectrometer or reflection and transmission photometer to get the color parameters via optical fiber or photoelectric detector.
-
product
EMI and EMC Test System
EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem.
-
product
Integrating Sphere With Holder Base
IS-*MA
1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40, all tubes such as T5/T8/T12, and all kinds of luminaries2. The hold base can be installed in the ceiling or down, it can be adjusted the height3. Hold base has four power cables connect to the outside Power Supply and max is 5KW4. The holder base is detachable. For some kinds of light sources you may need to change the position of the holder base.5. Diameter: IS-0.3M (0.3m), IS-0.5M (0.5m), IS-1.0MA (1.0m), IS-1.5MA (1.5m), IS-1.75MA (1.75m), IS-2.0MA (2.0m). Other sizes can be designed according to the customer’s request.6. The painting of integrating spheres is according to CIE Pub. No.84 (1989)
-
product
Electronic Ballast Tester
LCD for displaying waveforms and parameters directly, and it includes all the functions and technical parameters of WT3000. Reports can be printed if printer is connected. It also meets the latest requirements for electronic ballasts in international standards