Phase Standards
verify Phase Meters, Vector Voltmeters, Broadband Wattmeters and Power Analyzers, Resolvers and other Phase Sensitive Instruments.
See Also: Phase, Phasing, Phase Meters, Phase Angle, 3 Phase
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
Standard Air Capacitor Set, 1pF To 1000pF
16380A
-
The 16380A is a standard capacitor set consisting of four precision capacitors - 1pF (16381A), 10pF (16382A) 100pF (16383A), 1000pF (16384A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
Standard Voltage 9 Pin D-Type Connectors for Pickering Products
-
The connectors below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
Product
Phase Noise Tester 5MHz to 40GHz
Model 7340
-
Berkeley Nucleonics Corporation
Broad Frequency Range in a single compact instrument from 5MHz to 40GHz. Measurement offsets from .01Hz to 100MHz. Absolute Phase Noise - High Drift mode (ability to measure modulations, high drifting or unstable DUTs, etc.). AM (Absolute Amplitude Noise) measurements. Pulsed Measurement Capabilities. Transient Mode: measure WB Frequency, NB Frequency, NB Phase, NB Power (WB/NB being Wide Band and Narrow Band). Dual channel low-noise integrated power supplies.
-
Product
Open Standard Module (OSM)
-
Advantech's OSM, the SGeT standard for PCB soldering design with NXP platforms, boasts an ultra-low power, miniaturized design for AIoT endpoints.
-
Product
Capacitance Standard
SCA Series
-
The SCA Standard Capacitor series are highly stable cost-effective capacitance standards with low temperature coefficient, low losses and a wide range of values of 1 pF - 10,000 F. The cost and flexibility make this our most popular capacitance standard.
-
Product
Standard In-door Forward Optical Receiver
HR8636
-
Hangzhou Huatai Optic Tech. Co., Ltd.
HR8636 with standard configuration is a type of high index and universal in-door forward optical receiver. It adopts Philip optical receiving module. End-grade adopts power-doubling module. Optical connectors and RF connector can be installed at the front panel or back panel.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF1000
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations.
-
Product
Three Phase Multi-Function Meter Type DTSD999
-
Bofa Instrument & Equipment Co., Ltd
Measure total active energy、total reactive energy、forward active& reactive energy、 reverse active & reactive energy and total four quadrants reactive energy and time of sharing energy
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard GaN Amplifiers
-
A GaN (Gallium Nitride) amplifier is a power amplifier that uses GaN, a wide-bandgap semiconductor material, to provide high power density, efficiency, and frequency capabilities.
-
Product
Turns Ratio Meter 3 Phase
TR-MARK III 250V
-
The TR-MARK III 250V is the successor of the famous TR-MARK III. Besides an extended test voltage up to 250V, it offers new features and increased accuracy to make it a perfect system. A color LCD with back lighting and touch screen increases handling and user comfort. Two USB interfaces make it easy to store measurements on external storage devices and transfer easily to a personal computer or download nameplate data of transformer to test.
-
Product
Serrated, Multiple Point Waffle, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0H
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Standard Voltage 9 Pin D-Type Connector Blocks for Pickering Products
-
The connector blocks below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
Product
Portable Test Bench for Single Phase Energy Meter
SY2100
-
Hong Kong Songyang Industrial Ltd.
The new SY2100 series Portable electricity meter test equipment, designed from new DIGITAL WAVE COMPOUND TECHNOLOGY and according to International Standard, is newly intelligent equipment for energy meters. The equipment includes voltage/current source & standard meter, operated easily through front panel to preset directly all data of meter under test and test process.
-
Product
Standard Voltage 9-Pin D-Type Connector & Cable Accessories
-
The Standard Voltage 9-Pin D-Type connector is used on PXI switching products to provide a low density connector solution. Connection solutions for modules with High Voltage Rating D-Type connectors are also available.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2262AG-1C1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Three Phase Relay Testing
-
Our comprehensive and intuitive relay software speeds up testing times with a vast library of pre-defined test regimes or manual operation.
-
Product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-3W1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Cables - Connector to Unterminated
-
The connector to unterminated cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
AC Calibration Standard
1U647-001
-
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
Product
ACCUplace Macro Calibration Standard
AP-M Series
-
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-7
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Standard 2.40 (68.00) - 6.20 (176.00) Battery Probe
BIP-8
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Test Center (mil): 188Test Center (mm): 4.78Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 60Recommended Travel (mm): 1.52Overall Length (mil): 396Overall Length (mm): 10.06
-
Product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1P1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1C1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Turns Ratio Meter 3 Phase Rack
TR-MARK III R 250V
-
The TR-MARK III R 250V is the successor of the famous TR-MARK III R. Besides an extended test voltage up to 250V, it offers new features and increased accuracy to make it a perfect system. A color LCD with back lighting and touch screen increases handling and user comfort. Two USB interfaces make it easy to store measurements on external storage devices and transfer easily to a personal computer or download nameplate data of xformer to test.