Electrodes
-
Product
Straight Gold Disc Electrode
GDE-1
-
Straight gold disc electrode fabricated from high-purity gold and mounted in a PTFE body. Available in disc diameters of 1 mm, 2 mm, 3 mm, 4 mm, 5 mm, 6 mm, 8 mm, and 10 mm. Suitable for cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), electrocatalysis, corrosion studies, and electrochemical sensor research.
-
Product
Pure Titanium Plate & Mesh Electrodes
TPR-1-1
-
Pure titanium plate and mesh electrodes for electrolysis, corrosion testing, electroplating, and electrochemical research. Available in 10 × 10 mm, 20 × 20 mm, 30 × 30 mm, and 40 × 40 mm formats, with both plate and mesh structures. Custom sizes, thicknesses, and mounting configurations are available upon request.
-
Product
ITO (Indium Tin Oxide) Electrode
-
This quite unique material transmits only visible light whereas it does not transmit UV radiation. Our ITO electrodes consist of 100 nm thick of ITO layer deposited on quartz or borosilicate glass substrate (0.5 mm thick).
-
Product
pH 700 Benchtop pH Meter
-
The easy-to-use, microprocessor-based pH 700 benchtop meter measures pH, mV, relative mV, and temperature. The large, dual-display LCD provides excellent visibility—even from a distance. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Five-point pH calibration, with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers, makes for easy calibration no matter which requirement you need to meet. Meter features HOLD, ATC, selectable °F or °C measurement, recall of electrode slopand offset, and electrode diagnostics. The convenient pull-out quick reference card keeps procedures handy at all times. Meter accepts any pH or ORP electrodes with a BNC connector.
-
Product
Water Quality Products
-
When you need to perform critical water testing, look to us for an extensive selection of electrochemical meters, controllers, probes, electrodes, test kits, buffers, and standards. Our field and laboratory instrumentation include water analysis instruments for dissolved oxygen, temperature, pH, conductivity, salinity, and turbidity.
-
Product
Anti-Sulfurated Thick Film Type Resistors, Precision Type
ERJ-U2R/ERJ-U3R/ERJ-U6R Series
-
Panasonic Industrial Devices Sales Company of America
High Precision And High Resistance To Sulfurization In One Resistor!Panasonic's ERJ-U2R, ERJ-U3R, ERJ-U6R (ERJ-U*R Series) offers high precision and also provides anti-sulfurization characteristics that avoid an open circuit caused by a sulfide disconnection. High resistance to sulfurization is achieved through the use of an anti-sulfurated electrode structure and material in the manufacture of ERJ-U*R Series Resistors. AEC-Q200 Compliance and IEC 60115-8, JIS C 5201-8 and JEITA RC-2134C Reference Standards for the entire ERJ-U*R Series of High Precision, Thick Film Chip Resistors from Panasonic ensures optimal quality and reliability.
-
Product
Bonding Tester
PTR1102
-
In wire bonding in semiconductor manufacturing, electrodes are joined using gold wires of several tens of microns. In order to measure the pull (tensile) strength and ball shear (shear) strength of this gold wire, this machine has load detection accuracy and fine positioning accuracy. In addition, for the measurement of high load areas such as die shear strength and solder joint strength, this machine supports measurement in high load areas while maintaining accuracy in low load areas by replacing the sensor part.
-
Product
Micro Volume pH Monitor
UP-100
-
Redevelops HORIBA's founding pH measurement technology using new ultra-small capillary electrode. HORIBA's UP-100 affords ultra-low sample consumption of just 500 uL/measurement, enabling continuous pH monitoring for a variety of critical manufacturing processes that include Semiconductor (Cleaning, Etching and Plating); Chemical Manufacturing, Bio, Pharm, Food Processing, etc.Designed for 6 month continuous operation without operator intervention for minimizing downtime.
-
Product
Round-Head Platinum Sheet Electrode
CPR1
-
High-purity 99.99% platinum sheet electrode with chemically resistant PTFE round-head insulation for reliable electrochemical measurements. Suitable for electrolysis, electrocatalysis, corrosion testing, fuel-cell research and analytical electrochemistry. Standard sizes range from 5 x 5 mm to 30 x 30 mm, with custom dimensions and thickness options available.
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission)
HP-480
-
HP-480 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
Product
Nutrient- NH4, NO3
-
The HYDRA-DS Nitrate Analyzers are designed to monitor the nitrification process directly in the aeration basin or clarifier of a Waste Water Treatment Plant. The HYDRA Nitrate Sensor uses ISE technology to measure the Nitrate. Chloride ions interfere with the Nitrate Ion Electrode, compensation for the chloride ion interference on the nitrate electrode is preformed automatically in the T80 HYDRA-DS analyzer.
-
Product
Earth Testers
-
Sanwa Electric Instrument Co., Ltd
Most facilities have grounded electrical systems, so that in the event of a lightning strike or utility overvoltage, current will find a safe path to earth. A ground electrode provides the contact between the electrical system and the earth.
-
Product
pH Testr with Spear Electrode
pHSpear
-
Unique pHTestr with spear electrodepH is one of the key parameters measured in food processing. The Eutech waterproof pH Spear with tough, spear tip open pore sensor is a rugged, user-friendly tester ideal for direct measurement of solid or semi-solid samples such as cheese, meats, fruits, bread and other similar samples.
-
Product
200μm Flexible PET Interdigitated Electrode Chip
FPL1
-
200μm flexible PET IDE chip designed for biosensing, gas sensing, and humidity monitoring applications.
-
Product
Cell Production
-
JRT Photovoltaics GmbH & Co. KG
The production of lithium-ion cell batteries includes the three main process stages of electrode production, cell assembly and formation and aging. Automation is a critical factor for success, particularly in the process stage of cell assembly.
-
Product
250 and 260 Series pH Handheld Meter Kits
-
Get easy-to-read and accurate readings with auto-hold, auto-stable, and real-time measurements with stability indicators. The Environmental Express® Oakton® 200 series of water quality meters features an electrode status indicator, which shows the condition of the electrode after each calibration. Easily view electrode condition, reading stability, measured parameter, and temperature in one screen. Don’t worry about accuracy in fluctuating temperature—ATC ensures measurement accuracy. The simple user interface features adjustable auto shut-off time ranging from 1 to 30 minutes. Self-diagnosing meters display measurement and meter issues for fast fault finding and troubleshooting. Easily take measurements and conveniently store meter and electrodes with built-in foldable stand on the back of the meter. Two grooves on the side of the meter serve as electrode holders, to hold up to 2 electrodes. Choose from two series—the 250 series feature 500 data points (scroll thru on meter) while the 260 series features 1000 data points, a real-time clock, and USB communication for data down loads.
-
Product
Magnetic Glassy Carbon Electrode
DP-1
-
Dual-purpose glassy carbon working electrode for electrochemical measurements and SEM analysis. Available in 2–6 mm diameters with PTFE or PEEK housing, optional gold- or platinum-plated surfaces, and magnetic or detachable electrode configurations.
-
Product
Cross Flow Cell
-
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
Product
Handheld Water Quality Meters
LAQUA DO220
-
Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation0.01 mg/L or 0.1% DO resolutionCompensates salinity, temperature, and atmospheric pressure Allows up to 2 calibration points using galvanic DO electrode°C & °F temperature readingsWith real-time clock and date/time stamp for GLP complianceAuto log data; built-in memory can store up to 1000 dataAuto stable, auto hold, and real-time measurement modesAuto shut-off (programmable: up to 30 minutes)Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mmPhono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slipPowered by 2 x AA batteriesPackaged with galvanic electrode in carrying case3 years meter warranty
-
Product
Concrete Moisture Meter
7410
-
The electrodes transmit parallel low frequency signals, calibrated to give average moisture content by comparing the change in impedance between damp and acceptably dry concrete.Calibrated ready for use on concreteInstant readings on a clear, easy to read scaleFully portable, battery operated and non-destructive
-
Product
Industrial pH Meter (Four-Wire Analyzer)
HP-200-K
-
One-touch calibration function Realizes gentle measurement by combination with lead-free ORP electrode
-
Product
Universal Converter
C8000
-
Multi channel converter for all optek photometric and conductivity sensors and electrochemical pH electrodes. Flexible configuration of sensors, measuring ranges, units and product specific setups make the C8000 converter series a powerful device in process monitoring in both conventional and single-use systems.
-
Product
Rotating Ring Disk Electrode
RRDE-3A
-
RRDE-3A is a constant rotation system for use in hydrodynamic modulation rotating ring disk electrochemistry. A 7 mm diameter electrode with short stainless steel shaft provides for a miniature and concentric circle electrode system that is capable for highly accurate rotation and modulation even at radial modulation rates or wave forms.
-
Product
Screen-Printed Electrode Adapter For Electrochemical Workstations
PEP1
-
A screen-printed electrode adapter for electrochemical workstations, designed to provide stable electrical connections for electrochemical sensing and laboratory research.
-
Product
Fixture and Software for Open/Leak Inspection
-
In addition to jigs and fixtures for probing conductors and electrode pads, NIDEC-READ provides specialized software for test point selection and log analysis.
-
Product
Universal Electrode Holder Series
PSE-1
-
The PSE-1 Universal Electrode Holder Series is designed for secure mounting of platinum, gold, titanium, copper, stainless steel, graphite, and glassy carbon electrodes in electrochemical experiments. Available in PTFE and PEEK body options, with standard, extended, L-type, rod, and custom configurations to accommodate a wide range of cell designs and laboratory setups.
-
Product
Metal Sheet Working Electrodes
CS1
-
Metal sheet electrodes for electrochemical research, corrosion testing, and materials evaluation. Available in iron, copper, nickel, titanium, stainless steel, aluminum, zinc, silver, gold, platinum, tungsten, graphite, nickel foam, and MMO-coated titanium materials. Standard dimensions are available, with custom sizes and materials supported upon request.
-
Product
Dielectric Material Test Fixture
16453A
Test Fixture
The 16453A is designed for accurate dielectric constant and loss tangent measurements on the E4991A/4291A/B. It employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. The E4991A/4291A/B measures the capacitance created from the fixure, and option 002 firmware calculates the relative complex permittivity as described in the 16451B. Adjustment to insure parallel electrodes is required when using the 16451B. This adjustment is not required with the 16453A because the fixure has a flexible electrode that adjusts automatically to the material surface.
-
Product
U-Type Glassy Carbon Electrode | 3mm
CS1-1
-
U-Type Glassy Carbon Electrode with PTFE insulation for electrochemical applications. Suitable for CV, EIS, electrocatalysis, corrosion testing, and electrochemical sensor research. Available in standard and custom configurations.
-
Product
Glassy Carbon Electrode Coating Stand
EH1
-
Electrode stand for coating, drying, and temporary storage of glassy carbon electrodes, rotating disk electrodes (RDEs), and other laboratory electrodes. Available in 4-position, 9-position, and 12-position configurations.