Electrodes
-
Product
Continuity of Insulation Tester (High Voltage Method)
ZGQ-16B
-
Shanghai Dean Electrical Co., Ltd
Executive standard: GB/T4074.5-2008/IEC60851-5;Inspection standard: JB/T4279.13-2008Meet GB/T6109-2008 standard requirementsUsed to test the Insulation continuity (namely the pinhole number of enameled wire sample per unit length) of enameled round wires with nominal conductor diameter ranging from0.05mmto1.60mm;8 level test voltages can be selected by pressing button: 350V, 500V, 750V, 1000V, 1500V, 2000V, 2500V and 3000V;Test length ranging 0~99m;Application of SCM control.Automatically complete test process, display wire testing length and pinhole number;Brushless driving motor, guide pulley and take up pulley are equipotent.The electrode insulation to ground, using high resistance material of non-hygroscopic, no leakage, no tracking, easy to clean, Insulation thickness can ensure long-term 3000V voltage effect.Circuit board is subject to anti-static and moistureproof and long-time aging treatment, has more stable quality and higher durability;
-
Product
Dielectric Material Test Fixture
16453A
-
The 16453A is designed for accurate dielectric constant and loss tangent measurements on the E4991A/4291A/B. It employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. The E4991A/4291A/B measures the capacitance created from the fixure, and option 002 firmware calculates the relative complex permittivity as described in the 16451B. Adjustment to insure parallel electrodes is required when using the 16451B. This adjustment is not required with the 16453A because the fixure has a flexible electrode that adjusts automatically to the material surface.
-
Product
pH 450 Waterproof Portable Meter
-
Backlit, rugged waterproof meter is ideal for any environment!*Intuitive, user-friendly icons — electrode status displays pH slope*Grip-Clip™ electrode holder quickly and easily secures electrode to side of beaker or container*USB or RS-232 output for up to 500 data sets*Extended battery life or optional universal power adapter*Built-in stand with wall mount option allows for easy benchtop measurement or storage
-
Product
Solid Electrode Spectrochemical Cell
-
The spectroelectrochemical cell enables acquisition of infrared and Raman spectra of working electrode discs (variable sizes, up to 10 mm OD) under flowing solution. Working electrodes available include: Pt, Au, Ag, Cu, glassy carbon, etc. The cell uses a Pt-wire counter electrode and a Ag/AgCl reference electrode. For use with the EZpump peristaltic pump. Adapts to the Harrick Praying MantisTM Diffuse Reflection Accessory.
-
Product
Meter with "3-in-1" pH/Temperature Combi Electrode
pH 5+
-
Multi-Point Calibration (up to 5 points) with Auto-Buffer Recognition - choice of USA, NIST or pure water buffer standards with ±0.01 pH accuracy
-
Product
Conductivity Switches
-
B/W Controls offers a simple conductivity holder and electrode that can be configured for multiple measurement points.
-
Product
pH-Meters
-
Test soil pH, water pH, food pH and more quickly, easily and accurately with a digital pH Meter / pH Tester from PCE Instruments. Whether you’re looking for a compact, pocket, portable, handheld or tabletop pH Meter / pH Tester, you will find the best pH Meter / pH Tester for your application here. PCE Instruments also offers optional accessories such as pH Meter / pH Tester certified calibration certificates, oxygen probes and electrode storage solutions.
-
Product
Rotating Ring Disk Electrode
RRDE-3A
-
RRDE-3A is a constant rotation system for use in hydrodynamic modulation rotating ring disk electrochemistry. A 7 mm diameter electrode with short stainless steel shaft provides for a miniature and concentric circle electrode system that is capable for highly accurate rotation and modulation even at radial modulation rates or wave forms.
-
Product
Electric Insulating Oil Tester
PortaTest
-
Portatesters are easy to use. Based on the test standard, you select the corresponding test sequence. Then, the required test probe and the electrode gap for the selected test standard is displayed. The setting gauge, included in the scope of delivery, facilitates the adjustment of the electrode gap. Afterwards you fill the insulating oil in the test vessel and close the test chamber.
-
Product
Bulk Acoustic Wave Technology
BAW
-
Macom Technology Solutions Holdings Inc.
MACOM’s BAW product portfolio is ideal for high performance Industrial, Aerospace, Defense, and Communications applications that require critical frequency filtering. Our high-performance RF filters enable our customers manage signal integrity in the 1 to 6 GHz frequency range. Bulk Acoustic Wave Resonators consist of two metal electrodes above and below a layer of a piezoelectric material. The piezoelectric material converts an electrical signal to a mechanical signal and vice versa. The metal electrodes provide the connections to/from the piezo material. The frequency at which resonance occurs depends on the thickness of the combined metal-piezo-metal stack. Advances in thin-film piezoelectric fabrication have enabled BAW resonators to meet RF filtering challenges up to 6000 MHz using standard MEMS fabrication process. High-performance BAW resonators-based RF filters are made of piezoelectric material having high Q-factor (>3000) and high coupling coefficient. Currently, no competitive technology provides the same high performance for RF filter applications when compared to BAW resonator-based RF filter up to 6000 MHz for the same size and cost.
-
Product
Electrical Tomography Software
Res2dinv
-
This very popular software, developped by M.H.Loke, uses the method involving the Sasaki minimum squares inversion (1992) to produce a 2D sub-soil model starting from the data of apparent resistivity (up to 2000 electrodes). It is completely automatic and does not require that the user formulates a starting model. When using a state-of-art computer, the inversion of a single pseudosection will require only a few minutes.RES2DINV supports spreading types like Wenner, Schlumberger, Pole-Pole, Pole-Dipole, line Dipole, equatorial Dipole and other non-conventional spreading types.
-
Product
Handheld Water Quality Meters
LAQUA DO210
-
Measures dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation0.01 mg/L or 0.1% DO resolutionCompensates salinity, temperature, and atmospheric pressure Allows up to 2 calibration points using galvanic DO electrode°C & °F temperature readingsAuto log data; built-in memory can store up to 500 dataAuto stable, auto hold, and real-time measurement modesAuto shut-off (programmable: up to 30 minutes)Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mmCasing is IP67 waterproof/dustproof, shock & scratch resistant, non-slipPowered by 2 x AA batteriesPackaged with galvanic electrode in carrying case3 years meter warranty
-
Product
Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)
HC-300F
-
HC-300F is connected to a fluoride ion electrode (1009) to detect free fluoride ions in the sample water.(Total fluorine is not detected.) It is suitable for fluoride ion monitoring in effluent from factories, e.g., those of semiconductor FPD and glass manufacturers.
-
Product
Electrocardiogram Logger Sensor
NUL-218
-
Identical in its use to a regular medical ECG (electrocardiogram), this is a rather simple three lead based logger sensor. It presents a heartbeat graph that allows a thorough examination of the heart's electrical activity from three different angles. Unlike most ECG devices, this unit operates with non-disposable electrodes.
-
Product
Field-installation Type pH Meter (Two-Wire Transmission)
HP-300
-
HP-300 connects pH sensor and measures pHand temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
Product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196A
-
The 16196A surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results - reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement - now with the 16196 series, it’s easy to perform accurate and repeatable measurements.
-
Product
SMD Array Type LCR Test Fixture
16034H
-
The 16034H is designed for impedance evaluations of array-type SMD.The minimum SMD size that this fixture is adapted to evaluate is 1.6(L)x0.8(W)[mm]. Since the tip of the measurement electrodes are very thin and the device holder is extremely flat, the device can be shifted and the measurement electrodes can contact each of the elements of the array-type component.
-
Product
Intelligent Stirrer
Model 901
-
Intelligent chip design. Ability to set and store the stirring rate. Ability to switch between two kinds of stirring speed after pressing “PRM” button.Options of AC and DC. Applied in the field or in the incubator. MoreIntelligent chip design. Ability to set and store the stirring rate. Ability to switch between two kinds of stirring speed after pressing “PRM” button.Range: 0 to 2300 R/M (no load)Nice appearance, transparent coping designused with AC or DC, and a battery low voltage alarmused in lab, in incubator and brought outdoorsEquipped with strut and electrode holder, it can be used as agitating arc-spark standIP54 dustproof and splash proof.
-
Product
Rectal Probe For Mice (Isolated)
RET-3 ISO
-
• An isolated sensor (can be used with monitoring equipment where electrical interference from other electrodes may be present).• Reinforced strain relief for applications where probe is in more frequent use.• Smooth ball tip. Stainless steel shaft - 3/4'' long, .028'' diameter. Tip diameter .065'', 5 foot lead length. Time constant 0.5 seconds.
-
Product
Charge Meter
NK-1001A/NK-1002A
-
Probe-type charge meter that can easily measure the amount of discharge charge that causes static electricity destruction in the manufacturing, inspection, and assembly processes of electronic devices.Many ESD phenomena that impair electronic devices are represented by the CDM ( Device Charging Model). The CDM is a model that represents a phenomenon in which a high peak current flows at high speed when the device itself is charged and its external electrode is grounded. The coulomb meter measures the amount of discharge charge, which is the integral value of the current, with high accuracy.
-
Product
Rectal Probe For Rats (Isolated)
RET-2 ISO
-
• An isolated sensor (can be used with monitoring equipment where electrical interference from other electrodes may be present).• Reinforced strain relief for applications where probe is in more frequent use.• Smooth ball tip. Stainless steel shaft - '' long, .059'' diameter. Tip diameter .125'', 5 foot lead length. Time constant 0.8 seconds.
-
Product
Conductivity Logger Sensor
NUL-215
-
This logger sensor is based on a probe with two electrodes with known surface area and distance between them. A signal is supplied to the electrodes and by testing the signal behavior, the conductivity of the solution is calculated
-
Product
Digital Surface Resistance Test Kit
PAS-853BRM
-
- Surface Resistance Kit from 0.01 ohm to 9.99x1012 ohms- Nominal Full Range Tolerance Averages <±5%- Fully Automatic Resistance Range, Test Voltage and Electrification Period control- Determines if a surface is Dissipative, Conductive, or Insulative- Measures resistance point-to-point(Rtt) and point-to-ground (Rtg)- Measures resistance of Static Control Floors, ESD Work Surfaces and Packaging Material- Conforms to all ESD Association Standards for Resistive Characterization- Includes 2 each Conductive Rubber Electrodes- Packaged in a hard shell Carrying Case- Certificate of Calibration Traceable to NIST included
-
Product
Bottom Electrode SMD Test Fixture
16198A
-
Designed for impedance evaluations of bottom electrode SMDs and supports 201 (mm) and 402 (mm) sizes
-
Product
Reference Electrodes
-
Reference electrodes are widely used as: electrochemical measurements (CV, LSV, DPV, etc.) electrochemical devices (detectors for HPLC, biosensor, etc.)
-
Product
Electrode Measurement Meter
Ion 700
-
Ion-selective electrode measurement has never been this easy – or economical! The Ion 700 measures and records up to 100 data points with 0.01 resolution.
-
Product
Plug and Switch Testing
-
Applied to test electrical accessories heating conditions when connected to load current, whether the temperature rise of electrode is compliance with standard requirement or not. And it can effectively detect whether the plug bush is slants thin and whether plug and socket cooperated with all right.
-
Product
Low TCR High Power Current Sensing Resistors, Wide Terminal Type
-
Panasonic Industrial Devices Sales Company of America
Panasonic's ERJ-D1 and ERJ-D2 Series, Low TCR High Power Current Sensing Chip Resistors, achieve high power and low TCR (±100×10–6/°C) using a wide terminal electrode structure and original materials.These Resistors are suitable for small size/high power current detection and their low TCR enables high accuracy of current detection. The ERJ-D1 Series features higher rated power at 2W in a 1020 case size while the ERJ-D2 Series features 1W in a 0612 case size. These Resistors are AEC-Q200 Compliant and offer IEC 60115-8, JIS C 5201-8 and EIAJ RC-2134B Reference Standards ensuring optimal quality and reliability.
-
Product
High Voltage Thick Film Chip Resistors
HVTK (HVR)
-
*Highly reliable multilayer electrode construction*Higher component and equipment reliability*Excellent performance at high voltage*Reduced size of final equipment
-
Product
pH Testr with Spear Electrode
pHSpear
-
Unique pHTestr with spear electrodepH is one of the key parameters measured in food processing. The Eutech waterproof pH Spear with tough, spear tip open pore sensor is a rugged, user-friendly tester ideal for direct measurement of solid or semi-solid samples such as cheese, meats, fruits, bread and other similar samples.