Electrodes
-
product
Electrodes
Electrodes are offered in a wide variety of types. Spring electrodes are normally used in the inspection of pipes, although circular brush electrodes can also be used. Flat brush electrodes are used for flat surfaces. Brush materials can be of brass, steel or conductive neoprene construction. Internal electrodes are for testing internal pipe coatings.
-
product
pH Electrodes
A glass electrode is a type of ion-selective electrode made of a doped glass membrane that is sensitive to a specific ion. The most common application of ion-selective glass electrodes is for the measurement of pH. The pH electrode is an example of a glass electrode that is sensitive to hydrogen ions. Glass electrodes play an important part in the instrumentation for chemical analysis and physico-chemical studies.
-
product
Counter Electrodes
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.
-
product
Resistivity Cell For N1413 (50 Mm Electrodes)
N1424A
The N1424A is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424A to the B2985B/87B.
-
product
Working Electrodes for Flow Cell
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
product
Cells and Electrodes
Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.
-
product
Electrodes Sensor
6013
When selecting electrode sensors an important factor is to consider the specific characteristics of the liquid involved, the lengths required to obtain the desired control of levels, and the physical nature of the container.B/W Controls' line of electrodes has been developed to provide a practical, economical solution to almost every conceivable application and installation problem.Our electrode sensors are available in several varieties: solid rod (rigid), wire suspension, and standard gland plugs for high vibration applications. In addition, we offer custom options made per customer’s requirements.
-
product
Resistivity Cell For N1413 (26/50 Mm Electrodes)
N1424B
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
product
IDA Electrodes
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
product
Particle Size Analysis
Particle size analysis is a technical procedure to characterize the size distribution of particles in a powder or liquid sample. It is widely used in R&D and quality control in industries involved with nanotechnology, pharmaceuticals, cosmetics, food, electronic materials, sintering materials, Li-ion battery electrodes, etc.
-
product
Isolation Tester UIP
The devices of the UIP (Union Isolations Prüfer) isolation tester series are used to test the pore-free condition of corrosion protection coatings of pipes, vessels or plant system parts. The battery-powered device generates test voltages between 5 kV and 30 kV, which are applied to the grounded test object via test electrodes. The location of a defect is signalized by a spark-over with an additional audible warning.
-
product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
product
New Resistivity Inversion Software
EarthImager 3D
AGI is proud to introduce the new EarthImager 3D resistivity and IP inversion software. This software inverts resistivity and IP data acquired with electrodes arranged in boreholes and/or on the surface and presents a 3D volume of inverted resistivity data with advanced volume rendering technique. The final resistivity or IP image-volume can be rotated in any orientation, zoomed in and out, and translated to anywhere inside the image window in order to see the volume of interest in detail. Colors representing areas of less interest can be made transparent so that the shape of a pollution plume, for example, can be visible. With EarthImager, 3D resistivity inversion can be as easy as two steps: Read Data and Start Inversion with only a few mouse clicks.
-
product
Telurometer
AMRU-200
*The only meter on the market that implements all measurement methods:*Technical method of 2, 3 or 4 poles*Drive method (4/10μs, 8/20μs, 10/350μs).*Double-clamp method without the need for auxiliary electrodes.*Soil resistivity.
-
product
pH 2700 Benchtop Meters
Oakton 2700 meters meet GLP requirements - meters stamp all calibration and stored data with time/date. Nonvolatile memory stores up to 500 data sets to simplify documenting large volumes of pH or mV measurements. Meters automatically calculate and display electrode slope and offset - ideal for checking electrode quality. Order RS-232 and optional RS-232 to USB adapter separately. Advanced set-up options allow for a large degree of user customization. Datalogging intervals can be programmed into the meter for convenient continuous monitoring.
-
product
Direct Burial Half Cell Reference Electrode
DB-A
Model DB-A Copper-Copper/Sulfate Reference Electrode designed for direct burial for long term monitoring of buried or earth contacting structures.
-
product
Telurometer
AMRU-200 GPS
*The only meter on the market that implements all measurement methods:*Technical method of 2, 3 or 4 poles*Drive method (4/10μs, 8/20μs, 10/350μs).*Double-clamp method without the need for auxiliary electrodes.*Soil resistivity.
-
product
Electric Insulating Oil Tester
PortaTest
Portatesters are easy to use. Based on the test standard, you select the corresponding test sequence. Then, the required test probe and the electrode gap for the selected test standard is displayed. The setting gauge, included in the scope of delivery, facilitates the adjustment of the electrode gap. Afterwards you fill the insulating oil in the test vessel and close the test chamber.
-
product
Plant Auditor's Surface Resistance Kit
PMK-153
The PMK-153 Resistance Test Kit contains the instruments you need to take resistance measurements.The PMK-153 includes the PAS-853B Wide Range Ohmmeter with 5 pound Conductive Rubber Electrodes. The PAS-853B instrument is a wide range ohmmeter that measures accurately from 0.01 to 9.9x1012 ohms. In AUTO mode the instrument automatically adjusts resistance range and selects test voltage in accordance with standard practices outlined in ANSI/ESD STM11.11, and meets audit requirements of ESD TR53.
-
product
3D inversion geophysical software for Resistivity and Induced Polarization Data
RES3DINV
This program is designed to invert data collected with a rectangular grid of electrodes. The arrays supported include the pole-pole, pole-dipole, inline dipole-dipole, equatorial dipole-dipole and Wenner-Schlumberger. The RES3DINV program uses the smoothness-constrained least-squares inversion technique to produce a 3D model of the subsurface from the apparent resistivity data alone.
-
product
Earth Testers
Kyoritsu Electrical Instruments Works, Ltd.
Earth Ground Testing. Most facilities have grounded electrical systems, so that in the event of a lightning strike or utility overvoltage, current will find a safe path to earth. A ground electrode provides the contact between the electrical system and the earth.
-
product
Integrated Potentiostat and Multiplexer
EmStatMUX8
Based upon the EmStat range, there are two types of multiplexers to suit most types of sensor array work. The MUX8 is the most flexible offering the ability to connect arrays made of up to eight working electrodes in two or three electrode cell types and chips sharing a reference electrode and/or counter electrode. The MUX16 is suitable for sensor arrays or chips with sixteen working electrodes all sharing a RE and/or a CE. Both instruments are suitable for laminated layer corrosion analysis.The potentiostat is controlled and powered by USB and is used with PSTrace allowing for simultaneous sampling of each channel at a rate of 25 ms/channel. Standard packaging includes a shielded cable with connections for a working, a counter and a reference electrode by means of 2 mm banana connectors and mini-crocodile clips, a stripped end, Dsub-37 terminated flat cable and a USB cable. To make connections to chips simpler the Connection Terminal is an optional extra providing clearly marked screw terminals to the electrodes and can be directly joined to the ESMUX via their D-Sub connectors.
-
product
Panel Mounting Conductivity Transmitter
DO9786T-R1
output of a conductivity electrode with temperature compensation into a 4÷20 mA signal.
-
product
Fixture and Software for Open/Leak Inspection
In addition to jigs and fixtures for probing conductors and electrode pads, NIDEC-READ provides specialized software for test point selection and log analysis.
-
product
Intelligent Stirrer
Model 901
Intelligent chip design. Ability to set and store the stirring rate. Ability to switch between two kinds of stirring speed after pressing “PRM” button.Options of AC and DC. Applied in the field or in the incubator. MoreIntelligent chip design. Ability to set and store the stirring rate. Ability to switch between two kinds of stirring speed after pressing “PRM” button.Range: 0 to 2300 R/M (no load)Nice appearance, transparent coping designused with AC or DC, and a battery low voltage alarmused in lab, in incubator and brought outdoorsEquipped with strut and electrode holder, it can be used as agitating arc-spark standIP54 dustproof and splash proof.
-
product
2D Geophysical Inversion Software for Resistivity and Induced Polarization Data
RES2DINV
RES2DINV software is designed to interpolate and interpret field data of electrical geophysical prospecting (2D sounding) of electrical resistivity (conductivity) and induced polarization. The inversion of the resistivity and IP data is conducted by least-square method involving finite-element and finite-difference methods. The software can handle data from any electrode array, including Wenner (a, b, g), dipole-dipole, inline pole-dipole, pole-pole, Wenner-Schlumberger, equatorial pole-dipole and non-conventional arrays. Interpolate data from land, under water, and cross-borehole surveys. Easy data conversion from the most popular geophysical instruments including ABEM Lund, Syskal, AGI, PASI, IRIS, SCITREX, etc.
-
product
Meter with "3-in-1" pH/Temperature Combi Electrode
pH 5+
Multi-Point Calibration (up to 5 points) with Auto-Buffer Recognition - choice of USA, NIST or pure water buffer standards with ±0.01 pH accuracy
-
product
Bench pH/Conductivity/TDS Meter
CyberScan PC 510
Multi-parameter meters measures pH, Conductivity and TDS in single meter User-Customization for more accurate measurements with programmable functions like stability, electrode diagnosis - pH slope/offset/mV base value, etc.
-
product
9VT Neon Tube Tester
West Coast Custom Designs, LLC
When the antenna and/or the Disc are touched to the tubing wall or electrode wires, the tester will cause the viable tubing to illuminate.
-
product
Telurometer
AMRU 120